Quantitative Evaluation of Effects of Divergence Barrier on Collection Efficiency of Zero-tension Lysimeter Collection Efficiency of Zero-tension Lysimeter
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Zero-tension lysimeters (ZTL) have been widely applied to monitor soil solution flux and solute transport through soil layers in the vadose zone to the ground water under various conditions in research areas, such as the comprehensive utilization of agricultural water and soil resources as well as soil and water environment conservations. A capillary barrier that can cause flow divergence around the system will be created between undisturbed soil and ZTL as the ZTLs are installed in the field. Meanwhile, the water can overcome the capillary barrier and enter into ZTL only when the soil water is saturated above the contact plane of soil and ZTL. Thus, the efficiency of adopting ZTL for water collection decreases correspondingly. To improve the collection efficiency of ZTL, divergence barrier was added to ZTL (ZTLd), and the factors that can affect the collection efficiency of ZTL were examined, such as soil hydraulic property, soil texture, irrigation rate, initial soil water content and height of divergence barrier, and HYDRUS model was adopted. By measuring soil water flux from seepage face in a two-dimensional model and comparing it with applied flux in a one-dimensional model at the same depth, the collection efficiency was obtained. Three soil textures including sandy loam, loam and silt were considered, and the values of van Genuchten model parameters for test soils were not changed in HYDRUS model. Moreover, irrigation rates ranged from 100 mm to 1 000 mm, and height of divergence barrier ranged from 0 cm to 70 cm. Two initial soil water contents (i.e. 0.15 and 0.35 cm3/cm3) and two soil evaporation rates (i.e. 0.2 and 0.5 cm/d) were adopted. According to the results, the collection efficiency of ZTL without divergence barrier (ZTL0) was low due to lateral diversion of water above the seepage face. As for the ZTL0 under 1 000 mm irrigation rates, the collection efficiencies were 0~11%, 5%~13% and 6%~12% in the sandy loam, loam and silt soil, respectively. Due to the fact that more water was accumulated above the seepage face, the measured soil water flux increased as the divergence barrier was installed. However, the height of divergence barrier was reduced with the increase of irrigation rates as well as the decrease of water holding ability of soil and soil evaporation rates. When the height of divergence barrier was less than 20 cm and irrigation rate reached 1 000 mm under the condition of 0.35 cm3/cm3 initial soil water content and 0.2 cm/d soil evaporation rate, the collection efficiency of ZTLd was increased to 50%. Thus, coarse-textured soils, divergence barrier, low soil evaporation rate and high irrigation rates were preferred so as to measure water flux rate accurately by ZTLd. High initial soil water content (0.35 cm3/cm3) would lead to low collection efficiency of ZTLd in sandy loam, and collection efficiency of ZTL at a certain burial depth might not be suitable for other depths. According to the assumption of the study, all simulations were based on homogeneous soil without consideration of preferential flow, thus there was no effect of size on the collection efficiency. In conclusion, the results of this research can exert significance to the improvement of ZTL.

    Reference
    Related
    Cited by
Get Citation
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:March 18,2015
  • Revised:
  • Adopted:
  • Online: October 10,2015
  • Published: October 10,2015