Definition Evaluation of Auto Focus in Micro-vision Based on the Macro-micro Dual-drive
CSTR:
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    In order to avoid small field-of-view and limited depth-of-field of micro-vision, image definition based on gradient field and wavelet transformation was used. Microscope was set on the macro-micro dual-drive table in order to ensure the positioning precision. A selective focusing technique was developed to auto focus on the objects in different depth. Closed-loop feedback control was carried out. Experimental results showed that dynamic performance and stability of the system was satisfied, the response velocity of system increased from 0.3s-1 to 3s-1, meanwhile, collision-avoidance was executed according to vertical position relations computed by image definition.