Formulas for Trapped-oil Area and Relief-load Area of External Spur-gear Pump
CSTR:
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    In order to study quantitatively the trapped-oil phenomenon, with distance between meshing point and nodal point as a variable, a formula for calculating trapped-oil area and a fit formula for calculating relief-load area were derived from the geometrical relationship of gear transmission and positional relationship of relief groove. The calculated results were compared with the measured results from an accurate 3-D model. The results indicated that trapped-oil area and relief-load area could be expressed by a parabola with different index; simplified transition curve is feasible for calculating the two areas; fitting constant derived could be directly used aimed at different tooth number and module for calculating relief-load area. Finally, the two area-formulas were proved feasible to be used for forecasting the trapped oil pressure. 