    The inlet and outlet position of heat exchangers plays an important role in the mass flow rate distribution and pressure drop across the plate-fin oil cooler; the two geometrical parameters were studied by numerical simulation and verified by experimental work. In the simulation process, the porous media model was introduced to substitute the offset-strip-fin oil channel, and the non-uniformity coefficient was used to evaluate the mass flow rate distribution.