气液两相感应式静电喷头性能试验
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:

国家自然科学基金资助项目(30971940) 、国家国际科技合作资助项目(2010DFA34570)和中央高校基本科研业务费专项资金资助项目(2010JS044)


Performance of Two-phase Gas-liquid Electrostatic Induction Nozzle
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    对研制的气液两相感应式静电喷头进行了性能试验研究。结果表明:与常规喷雾相比,雾滴在叶片正面的沉积量和覆盖率分别增加了43.03%和22.07%,且在叶片背面覆盖率达30.95%;当气体流量为1.4 m3/h,喷量为60 mL/min,电压为1000V时,荷质比可以达到3.2mC/kg,可以有效增加荷电沉积;最优工作参数组合为气液比0.18、喷雾角度0°、电压1000 V。

    Abstract:

    The performance research on a two-phase gas-liquid electrostatic induction nozzle was carried out in the lab. The results showed that the droplets deposition and coverage ratio on the upper leaf surfaces achieved by electrostatic spraying were increased by 43.03% and 22.07%, respectively. The coverage ratio on the down leaf surfaces was up to 30.95%; when gas flow rate was 1.4m3/h, liquid flow rate was 60mL/min, voltage was 1000 V, chargetomass ratio could reach to 3.2mC/kg, which was high enough for electrostatic spraying. The optimum work parameters were: gasliquid ratio of 0.18, spraying angle of 0°, and voltage of 1000 V. 

    参考文献
    相似文献
    引证文献
引用本文

张京,宫帅,宋坚利,周继中,何雄奎.气液两相感应式静电喷头性能试验[J].农业机械学报,2011,42(12):107-110,120.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2011-12-19
  • 出版日期: