    摘要:

    设计了脉冲强光杀菌装置及其检测系统。以脉冲氙灯作为光源,其充电输入电压是0.8~3kV。利用脉冲强光杀菌装置对选定菌种进行了初步杀菌试验。试验结果表明,脉冲强光技术的杀菌效果十分明显。增加闪照次数、输入电压或菌液透光率都能够提高杀菌率至100%;透光率为100%、菌液厚度超过3.4mm时,大肠杆菌的致死率达

    Abstract:

    100%。The pulse glare sterilization is a kind of new technology. The design of experimental equipment and its detecting system were finished. The pulse xeon was taken as a light source. Its input voltage was 0.8 to 3kV. The primary experiments have been done by the equipment to a special bacterium. The results showed that flash frequency, input voltage, bacterium liquid depth and relative transmittance are the main factors. The sterilizing rate could reach 100% when the values of these factors were increased. And the effects of pulse glare sterilization are very remarkable. This equipment can be applied in the processing and storage of agricultural products.