土壤钾离子非接触电导检测装置设计与试验
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:

国家重点研发计划项目(2017YFD0700501-2)


Design and Experiment of Capacitively-coupled Contactless Conductivity Detection Device for Rapid Measurement of Soil Potassium Ion
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    为确保土壤钾离子检测的时效性和准确性,设计了非接触电导检测装置。首先,设计与毛细管配套的非接触式电导检测池,以金属圆筒结合导电银胶构建激励电极、屏蔽电极和接收电极。其次,构建非接触式电导检测器,包括激励信号发生电路、前置放大电路及检波放大电路,搭建了一个板级的激励信号发生电路,该电路采用考毕兹振荡器电路匹配高频变压器的方案。前置放大电路采用跨阻放大拓扑,检波放大电路将前置放大电路输出的毫伏级交流电压信号,通过整流、调零、程控放大,得到一个固定范围的直流电压,用于上位机采集。通过电导率的变化波形可以分析出土壤溶液中的钾离子含量。最后,采用设计的非接触式电导检测装置对6种标准土样的钾离子含量进行初步检测分析。结果表明,6种土壤样品的钾离子含量测试结果与标准值的趋势一致,说明此套非接触式电导检测装置能够完成土壤样品的初步检测,并与标准值存在相关关系。

    Abstract:

    At present study, a capacitively-coupled contactless conductivity detection (C4D) device integrated with capillary electrophoresis was expected to fulfill rapid detection of potassium ion concentration in soil. The device contained a C4D cell and a C4D detector. Firstly, a C4D cell matched with the 360 μm fused quartz capillary was designed. In the C4D cell, a receiving electrode, a shielding electrode and an exciting electrode were constructed by metal cylinder electrode with conductive silver paste. The lengths of the exciting electrode and the receiving electrode were both 10mm, and the distance between the two electrodes was 2mm. Secondly, the C4D detector included exciting signal generator circuit, pre-amplifier receiving circuit and detection amplifier circuit. After the potassium ion electrophoresis tests, the optimal excitation signal for soil solution analysis was determined as 136kHz, 80V sine wave. Finally, the C4D device was used in preliminary test of the potassium ion contained in six kinds of soil samples. The six national standard soil samples were digested by pure water, and then the solutions were filtered as test samples. The potassium ion test results of the six soil samples tended to correlate with the standard values. The results indicated that the C4D device had potential to complete preliminary tests of actual soil samples. The proposed capacitively-coupled contactless conductivity detection method modulated the soil samples for the first time. The optimized detection method can be used for rapid on-site soil nutrient detection in the future.

    参考文献
    相似文献
    引证文献
引用本文

张俊卿,高钧,陈翔宇,王儒敬,张正勇,魏圆圆.土壤钾离子非接触电导检测装置设计与试验[J].农业机械学报,2018,49(s1):360-364,392. ZHANG Junqing, GAO Jun, CHEN Xiangyu, WANG Rujing, ZHANG Zhengyong, WEI Yuanyuan. Design and Experiment of Capacitively-coupled Contactless Conductivity Detection Device for Rapid Measurement of Soil Potassium Ion[J]. Transactions of the Chinese Society for Agricultural Machinery,2018,49(s1):360-364,392.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2018-07-01
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2018-11-10
  • 出版日期: