带可调进口导叶轴流泵装置水力性能数值分析
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:

国家自然科学基金资助项目(51279173、51376155)、“十二五”农村领域国家科技计划资助项目(2012BAD08B03-2)和扬州大学高层次人才科研启动资金资助项目


Numerical Simulation on Hydraulic Performance of Axial-flow Pumping System with Adjustable Inlet Guide Vanes
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    根据轴流泵进口导叶片的设计要求,设计了可调进口导叶并开展了不同安放角进口导叶轴流泵装置的三维定常数值计算,获取了进口导叶对轴流泵装置水力性能调节的综合特性曲线,建立了带可调进口导叶轴流泵装置水力性能预测的多元非线性回归预测数学模型。依据数值计算结果和速度三角形分析了可调进口导叶对转轮及轴流泵装置水力性能的影响,结果表明:在进口导叶安放角0°时,相比不带可调进口导叶的轴流泵装置,在高效区及小流量工况时带进口导叶泵装置的能量性能变化很小,大流量工况时进口导叶的水力损失较大进而导致带进口导叶泵装置的效率下降幅度较大。随进口导叶安放角由0°逐渐向正角度增大时,泵装置的最优工况向小流量方向偏移,泵装置的流量效率曲线呈现出整体下降的趋势;随进口导叶安放角由0°逐渐向负角度减小时,泵装置的最高效率先增大后减小,但泵装置的最高效率点对应的流量未发生改变。

    Abstract:

    The theoretical analysis and numerical simulation method were used to study the influence of inlet guide vane on the hydraulic performance of axial-flow pumping system. The inlet guide vane was designed based on design requirements. The three-dimensional internal flow of axial flow pumping system was simulated in different installation angles of inlet guide vane. Overall performance curves of axial-flow pumping system with adjusted inlet guide vane were obtained and the multiple non-liner regression prediction mathematical models of the hydraulic performance were established based on the results of numerical simulation and velocity triangle analysis. Compared with the pumping system without inlet guide vane, the hydraulic performance of pumping system with inlet guide vane changes little in the high efficiency area and small flow rate condition, but the efficiency of pumping system drops greatly because the hydraulic loss of inlet guide vane increases greatly in the large flow rate condition. With the increase of positive installation angle of inlet guide vane, the high efficiency operating condition is offset to small flow rate and the whole efficiency curves of pumping system would drop. While, with the decrease of negative installation angle, the high efficiency of pumping system increases firstly then decreases. The flow rate doesn’t change in the high efficiency operating condition of different negative installation angles.

    参考文献
    相似文献
    引证文献
引用本文

杨 帆,刘 超,汤方平,周济人,成 立.带可调进口导叶轴流泵装置水力性能数值分析[J].农业机械学报,2014,45(5):51-58. Yang Fan, Liu Chao, Tang Fangping, Zhou Jiren, Cheng Li. Numerical Simulation on Hydraulic Performance of Axial-flow Pumping System with Adjustable Inlet Guide Vanes[J]. Transactions of the Chinese Society for Agricultural Machinery,2014,45(5):51-58.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2013-04-23
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2014-05-10
  • 出版日期: 2014-05-10